Table of contents
This guide explains, from an engineering perspective, the nature of battery internal resistance, the factors that affect it and its interaction with motor efficiency. The aim is to highlight the often overlooked chain of losses and show practical ways to significantly improve overall efficiency.
1. The overlooked energy drain
In off-grid systems, RV power systems or electric boats, users often focus on capacity, discharge current and range – but the battery's internal resistance often goes unnoticed, even though it has a major impact on efficiency.
When a motor starts, currents can surge to dozens or even over 100 A. Internal resistance then determines how much electrical energy is lost as heat at the battery itself. These losses are not directly visible, but they occur with every start and load change – affecting system performance and range.
Key takeaway: The greater the internal resistance, the higher the losses at the same current – and the less usable power reaches the motor.
2. What is battery internal resistance?
Battery internal resistance (Ri) is the sum of all resistances that oppose current flow inside the battery. It consists of:
- Ohmic component: Conductors, electrode material, current collectors and more.
- Polarization component: Reaction kinetics and ion migration; dependent on temperature, current rate (C-rate) and SOC.
During discharge, a voltage drop occurs across Ri (Udrop = I × Ri), reducing the terminal voltage – the source of the losses.
3. The mathematics of power loss
Power loss: Ploss = I² × Ri
Efficiency estimate (simplified approximation): η ≈ 1 − (I × Ri / Ubatt)
Example
LiFePO₄ battery 12,8 V, Ri = 5 mΩ (0,005 Ω), motor current 80 A:
- Power loss: Ploss = 80² × 0,005 = 32 W
- At 1000 W motor input power, that is ≈ 3,2 % loss – under continuous load or with 100 A peaks, this quickly adds up and can accelerate heating and aging.
4. Chain reaction: internal resistance → controller → motor
The energy chain can be divided into three stages:
- Battery → Internal resistance losses → Controller
- Controller → MOSFET/PCB trace losses → Motor terminals
- Motor → Copper & iron losses → Mechanical power
If Ri is high, losses increase in stage 1, leading to the following effects:
- Lower starting torque: less effective voltage at the controller/motor.
- Input voltage drop: possible controller undervoltage shutdown.
- Reduced overall efficiency: shorter runtime/range.
5. Five key factors affecting Ri
- Cell chemistry & quality: LiFePO₄ cells typically 1,5–3 mΩ/cell; significantly better than lead-acid (≈ 10–15 mΩ/cell). A+ grading improves consistency.
- Temperature: In cold conditions, the polarization component rises significantly; at −10 °C, Ri can increase to > three times its original value.
- State of charge: Ri rises at the extremes (near full/near empty); 20–80 % SOC is optimal.
- Aging/cycles: Electrolyte aging and material loss increase Ri – a visible indicator of capacity degradation.
- Contact & connection resistance: Terminal clamps, busbars, crimps, screw connections – oxidation/loosening adds resistance.
6. How to reduce system resistance & losses
1. Cells & construction
High-quality A+ cells with lower Ri; laser-welded connectors and copper busbars minimize connection resistance.
2. BMS design
Power MOSFETs in parallel configurations, thick copper layers (PCB) and low-resistance protection paths keep voltage drop low.
3. Cables & terminals
Adequate cross-section and tightening torque in line with standards (e.g. 12 N·m) reduce cable losses and heating.
4. Temperature management
Preheat in cold conditions or use self-heating batteries. For every −10 °C, Ri can increase by ≈ 20–30 %.
5. Operating range
20–80 % SOC is preferable; prolonged full charge or deep discharge increases Ri and aging.
6. Monitoring & balancing
Bluetooth monitoring (cell voltage, temperature, Ri trend) and regular balancing prevent hot spots.
7. Matching the battery & motor
The battery's continuous discharge rate must match the motor's power requirements – looking only at capacity is a common mistake.
Example
- Motor: 800 W, peak current 100 A.
- Suitable battery: Continuous ≥ 100 A, peak ≥ 200 A, Ri ≤ 5 mΩ → voltage drop ≈ 0,5 V, η remains ≈ 96 %.
- Unsuitable battery: Ri = 10 mΩ → drop ≈ 1 V; ≈ 8 % loss, noticeably lower speed.
Rule of thumb: Ri × I ≤ 3 % of the nominal voltage, to keep motor voltage stable.
8. Conclusion
The battery's internal resistance is often underestimated – yet it significantly affects discharge efficiency, temperature behavior, motor performance, controller stability and range.
- Every +1 mΩ means an additional 10 W of loss at 100 A.
- +10 °C battery temperature can double the aging rate.
- Every undervoltage shutdown reduces availability and service life.
High overall efficiency comes down to many details: cell selection, conductor cross-section, thermal management, BMS topology – real efficiency gains often lie in a few milliohms.


Share:
Proper LiFePO4 Battery Storage: Prevent Capacity Loss
From Campsite Electricity to Onboard Power: A 12-V Battery for Your Motorhome?